PC30
Product Name | Ceramic Pressure sensors | Residual Temperature Effects (Zero & Sensitivity) | ≤±0.03%FS/℃ |
Model | PC30 | Combined Error (Non-Linearity + Hysteresis) | ≤±0.4%FS[Terminal based] |
Rated Range | 0-1bar...0-400bar | Repeatability | ≤±0.1%FS |
Dimensions&Height | Diameter φ30mm, Varies Thickness | Zero Offset | ≤±0.2mV/V |
Maximum excitation voltage | 30Vdc | Zero point Long Term Stability @ 25 °C | ±0.2%FS |
Bridge Impedance | 12KΩ±30% | Burst Pressure | Approximately 2 times the rated capacity |
Full Scale Output Signal | 4.0mV/V,typ | Material in contact with fluid | Alumina Al2 O3 – 96% |
Operating Temperature Range | -40~135℃ | Main Applications | Pneumatic, hydraulic, medical equipments... |